What We Do

Three Services.

One Partner.

From the first audit to ongoing maintenance and certified installation, AJC Fire Stopping manages the entire fire door compliance process in-house. No handoffs. No gaps.

Fire Door Audits

A certified inspection of every fire door set, covering gaps, seals, ironmongery, self-closers, glazing, and frame integrity. Each report includes clear written findings, photographic evidence, and a prioritised action plan suitable for regulators and insurers.

  • Door-by-Door Schedule

    Complete inventory with individual pass/fail status, defect notes and gap measurements

  • Photographic Evidence

    Every defect is photographed and clearly referenced, providing evidence for audits and enforcement.

  • Prioritised Action Plan

    Defects ranked Critical / Advisory / Recommended so you act in the right order

  • Compliance Certificate

    Signed certificate confirming inspection to FSO 2005, BS 8214 and BS 9999

  • Automatic Reminders

    You’ll receive an automatic reminder 30 days before your next audit is due, giving you time to schedule it in advance.

Door leaf, frame & wall integrity

Structural assessment against BS 8214 and BS 9999 requirements

Gap measurements & threshold

All gaps and thesholds precision-measured

Intumescent & cold smoke seals

Integrity, damage and specification checked against door rating

Self-closers, hinges & ironmongery

CE-marked components verified for condition and correct operation

Fire safety signage & glazing

Signage clarity and fire-rated glazing integrity confirmed

Sample Output

What A Report Looks Like

Each door has its own record showing pass or fail status, measured gaps, component condition, and any required remedial actions. The records are structured to meet the needs of regulators, insurers, and your fire risk assessment.

  • Available as PDF and digital format
  • Inspector certification details included
  • Shareable with insurer or fire authority

Fire Door Audit Report — Sample

  • Door 001 — Ground Floor LobbyPASS
  • Door 002 — 1st Floor StairwellFAIL — ACTION
  • Door 003 — Plant RoomPASS
  • Door 004 — 2nd Floor CorridorADVISORY
  • Door 005 — Rear ExitFAIL — URGENT
  • Door 006 — ReceptionPASS
Inspector: AJC FS CertifiedBM Trada Q-Mark

Your Legal Requirement

Who needs fire door audits, and how often

Under the Regulatory Reform (Fire Safety) Order 2005, the Responsible Person for any non-domestic building must ensure fire doors are regularly inspected and maintained. The Fire Safety (England) Regulations 2022 require communal fire doors in residential blocks over 11 metres to be inspected every three months, and flat entrance doors annually. Non-compliance can result in prosecution, unlimited fines, or imprisonment.

Get Compliant

Maintenance
& Repair

We fix defects using certified components to manufacturer specification. Whether from an audit finding or a routine service visit, every repair is documented and added to your compliance record.

  • Service Contracts

    Ongoing scheduled maintenance, we manage the calendar, you maintain compliance

  • Remediation First

    We repair before replacing, saving cost while maintaining full compliance

  • Full Documentation

    Every repair recorded with date, component, technician and photographic evidence

Intumescent Seal Replacement

Certified strip matched to door rating

COMPLETE

Self-Closer Adjustment

Positive latch confirmed on every closure

COMPLETE

Hinge Replacement

CE-marked to BS EN 1935, correctly installed

CERTIFIED

Gap Correction

Frame adjusted to 3mm tolerance

COMPLETE

Cold Smoke Seal

Integrity verified and replaced

CERTIFIED

Repair Coverage

What We Fix

Every component of a fire door assembly contributes to its fire resistance. A single failed component can compromise an otherwise compliant door.

Self-closing Devices

Adjustment, replacement and testing, positive latching on every closure, every time

Intumescent Seals

Replacement with certified strips matched to the door's rated fire resistance

Cold Smoke Seals

Prevents smoke spread before heat activates intumescent, first line of defence

Hinges & Ironmongery

CE-marked replacements installed to BS EN 1935, the specification that matters in a fire

Gap Correction

Frame and leaf adjustment to bring all gaps within regulatory tolerance

Glazing & Apertures

Certified fire-rated glazing checked and replaced where integrity is compromised

Fire Door
Installation

New and replacement fire door sets, FD30 and FD60, supplied and installed by certified technicians. Every installation is fully documented with a completion certificate, ready for your compliance file from day one.

  • New Build & Retrofit

    Structural adjustments handled to achieve correct tolerances in any opening

  • Heritage & Listed Buildings

    Sympathetic solutions, fire performance without compromising architectural character

  • Completion Certificate

    Every installation signed off with a certificate and photographic evidence, valid from day one

FD30

30-Minute Fire Resistance

Standard compartmentation for corridors, offices, education and commercial spaces

  • ✓Certified door set & ironmongery
  • ✓Intumescent & cold smoke seals
  • ✓Self-closer installed and tested

FD60

60-Minute Fire Resistance

Higher-risk areas, plant rooms, high-rise, protected escape routes

  • ✓Enhanced fire resistance rating
  • ✓Completion certificate day one
  • ✓All sectors and building types

Audit. Maintain. Install.

One partner for every stage of fire door compliance,
no handoffs, no accountability gaps, no starting again with a new contractor.

Get a Free Quote